Product SKUs |
A+ Server AS -2124BT-HTR
|
Motherboard |
Super H12DST-B
|
CPU |
- Dual Socket SP3
- AMD EPYC™ 7002/7003 Series Processors
|
Note |
- Supports up to 200W TDP CPUs (Air Cooled)
|
Memory |
- Slot Count: 16 DIMM slots
- Max Memory (1DPC): Up to 4TB 3200MT/s ECC DDR4 RDIMM/LRDIMM
- View Memory Options
|
Memory Voltage |
|
Chipset |
|
Network Connectivity |
|
IPMI |
- Support for Intelligent Platform Management Interface v.2.0
- IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
|
LAN |
- 1 RJ45 1 GbE Dedicated BMC LAN port
|
USB |
|
Video |
|
DOM |
- 1 SuperDOM (Disk on Module) port
|
BIOS Type |
|
Software |
- Supermicro Server Manager (SSM)
- Supermicro Update Manager (SUM)
- Supermicro SuperDoctor® 5 (SD5)
- KVM with dedicated LAN
- IPMI 2.0
- Watch Dog
|
Power configurations |
- ACPI/APM Power Management
|
Hardware |
- Trusted Platform Module (TPM) 2.0
- Silicon Root of Trust (RoT) – NIST 800-193 Compliant
|
Features |
- Cryptographically Signed Firmware
- Secure Boot
- Secure Firmware Updates
- Automatic Firmware Recovery
- System Lockdown
|
Form Factor |
|
Model |
|
Height |
|
Width |
|
Depth |
|
Package |
- 9.76" (H) x 24.65" (W) x 45.28" (D)
|
Weight |
- Gross Weight: 96.6 lbs (43.8 kg)
- Net Weight: 66.1 lbs (30 kg)
|
Available Color |
- Black front & silver body
|
PCI-Express (PCIe) Configuration |
|
M.2 |
- 1 M.2 PCIe 3.0 x4 NVMe/SATA slot (M-key 2280/22110)
|
Drive Bays Configuration |
|
M.2 |
|
Fans |
- 4 Heavy-duty PWM 8cm Fan(s)
|
Power Supply |
2x 2200W Redundant (1 + 1) Titanium Level (96%) power supplies |
Dimension (WxHxL) |
45 x 40 x 480 mm |
Total Output Power |
for CCC only |
Input |
1200W: 100-127Vac 1200W: 100-127Vac / 50-60Hz 2090W: 180-220Vac (for UL/cUL only) 2090W: 180-220Vac / 50-60Hz (for UL/cUL safety rating only) 1800W: 200-220Vac 1800W: 200-220Vac / 50-60Hz (for TUV/CB/others safety rating only) 1980W: 220-230Vac 1980W: 220-230Vac / 50-60Hz (for TUV/CB/others safety rating only) 2200W: 220-240Vac (for UL/cUL only) 2200W: 220-240Vac / 50-60Hz (for UL/cUL safety rating only) 2090W: 230-240Vac 2090W: 230-240Vdc (for CCC only) 2090W: 230-240Vdc / 50-60Hz (for CQC safety rating only) 2090W: 230-240Vac / 50-60Hz (for TUV/CB/others safety rating only) |
+12V |
Max: 100A / Min: 0A (100Vac-127Vac) (for TUV/CB/others safety rating only) Max: 174.17A / Min: 0A (180Vac-220Vac) (for UL/cUL safety rating only) Max: 150A / Min: 0A (200Vac-220Vac) (for TUV/CB/others safety rating only) Max: 165A / Min: 0A (220Vac-230Vac) (for TUV/CB/others safety rating only) Max: 183.33A / Min: 0A (220Vac-240Vac) (for UL/cUL safety rating only) Max: 174.17A / Min: 0A (230Vdc-240Vdc) (for CQC safety rating only) Max: 174.17A / Min: 0A (230Vac-240Vac) (for TUV/CB/others safety rating only) Max: 100A / Min: 0A (100-127Vac) Max: 150A / Min: 0A (200-220Vac) Max: 165A / Min: 0A (220-230Vac) Max: 174.17A / Min: 0A (180-220Vac, UL/cUL only) Max: 174.17A / Min: 0A (230-240Vac) Max: 174.17A / Min: 0A (230-240Vdc, CCC only) Max: 183.33A / Min: 0A (220-240Vac, UL/cUL only) |
12V SB |
Max: 2.1A / Min: 0A |
Output Type |
Backplanes (connector) |
ROHS |
|
Environmental Spec. |
- Operating Temperature: 10°C ~ 30°C (50°F ~ 86°F)
- Non-operating Temperature: -40°C to 60°C (-40°F to 140°F)
- Operating Relative Humidity: 8% to 90% (non-condensing)
- Non-operating Relative Humidity: 5% to 95% (non-condensing)
|